| Elliott Sound Products | Power Savers |
The Great "Power Saver" Fraud
Copyright © 2011 - Rod Elliott (ESP)
Main Index
More and more often lately, we see glowing reports on TV and in the popular press about the latest inventor who's managed to come up with a device that will save you anything from 25 to 35% on your electricity bill. We should not be alarmed (apparently) to discover that most of the "inventors" of these revolutionary products seem to be uneducated and are unattached to any research arm of a university or similar. Almost all advertised "power savers" on the Net are a scam - 100% of plug-in "power savers" are a scam.
While backyard discoveries are certainly possible, it's very unlikely that anyone who owns no more than a digital multimeter and a $30 power meter from the local electronics store will be able to compete with large labs that specialise in the accurate measurement of power. Huge sums are invested to obtain relatively small gains in some cases. (see footnote) My own equipment is considerably more sophisticated than that used by most of those who claim to be able to reduce your electricity bill, yet they persist.
To some extent, I think that many of these "inventors" may actually believe that their device works, but this is because they completely misunderstand the concept of power, power factor, apparent power, reactive loads and non-linear loads. This is a very complex field, and one that power companies are well aware of - but not because it will save you, the residential consumer, a single solitary cent. Consumers are charged for actual power (kWh meters measure only the real power consumed, not the reactive component), and "power savers" will result in real savings that range from negligible to negative.
Power companies use large scale "power savers" to correct for poor power factor, because a low power factor means that they cannot fully utilise their infrastructure to deliver chargeable power to consumers. This increases the system losses and the cost of distribution, and reduces profits. Power companies have used the technology that the fraudsters will call "revolutionary" for years - power generation and distribution has been going on for over 100 years, and you can be certain that they have overlooked very little that will improve the efficiency of delivery.
As with all things, there are compromises (some very significant), but there is no new technology, and you can be certain that backyard inventors are extremely unlikely to compete on the scientific level. The vast majority either don't know what they are talking about or are lying, as we will see here.
A great many of these fraudulent sellers will appeal to the green lobby, and try to tell you that without their box you are needlessly consuming precious resources and ruining the planet. I argue that making, shipping and installing these devices will cause far more damage to the planet than not using them - and that's based on the false assumption that they work. Since they don't work, they are mostly planet hostile. Corrected power factor does benefit the electricity provider, but only if it's done properly ... the vast majority of these boxes do nothing properly.
As discussed further in the conclusion, no major electrical goods manufacturer or supplier sells one anywhere, and they really do have the wherewithal to develop the product properly if there was any reason to do so. They don't sell them for one simple reason - they don't want the embarrassment of prosecution for selling goods that don't do what they claim. These frauds are largely the territory of websites and eBay, often so the seller can disappear in a hurry if needs be. If you still need convincing, read on ...
![]() | Note that power companies and universities the world over are looking for tiny incremental improvements to the power grid components. A saving or improvement of 0.1% is less than trivial to almost all households, but could result in huge savings for a power company. The equipment used by the "power saver" brigade would be unable to measure such a small change reliably, yet we are expected to believe that they can do in the home workshop that which cannot be done by massively funded research labs. This alone should be enough to convince you that they are charlatans.
In all cases throughout article, I will place "power saver" in quotes - this is done to indicate that it is a slogan that bears no resemblance to reality. |
This is a topic that is very poorly understood. Even a great many engineers will get it badly wrong, especially if they have only ever dealt with motors and transformers (large or small). It is only fairly recently that we have seen a proliferation of non-linear loads, where the voltage and current waveforms are not the same.
Incandescent lamps (now sadly being banned in many countries), electric heaters (radiant or oil-filled), kettles/ jugs, toasters, electric stoves and electric blankets (amongst other similar things) are all resistive loads. These all maintain the voltage and current in phase, and have a unity (ideal) power factor. Dimmers or other electronics that alter the current waveform will affect the power factor, even though voltage and current are in phase. This is covered in more detail below, because it's vitally important to out understanding of the topic.
The traditional calculation for power factor only considers the relative phase angle between voltage and current (commonly known as cos (cosine) Φ), but this only applies when the voltage and current waveforms are sinewaves. So, assuming that the current is 45° out of phase with the voltage (lagging or leading), the power factor is ...
PF = cos Φ = cos 45 = 0.707
If the load is inductive, such as a lightly loaded transformer or motor, the power factor is called lagging - the current waveform occurs after the voltage waveform. This is by far the most common form of linear load that we see. When fully loaded both motors and transformers will typically have a power factor (PF) of 0.9 or better, but these basic machines are not often used at full load in households. Single phase motors in particular need extra power to be able to start under load, and few domestic transformers will be heavily loaded. A simple phase shifted voltage, current and power waveform is shown below.

Here we see a schematic of the most basic partially inductive load. The inductive part of the load impedance consumes no power from the mains nor does it produce any power (work) to the load. It is simply a necessary part of the equipment, and exists whether we like it or not. Because there is an inductive component, there is a phase shift in the current waveform, which is retarded by very close to 45°. As shown above, the power factor is 0.707
Also shown is a capacitor that we can switch in or out of the circuit. More on this shortly. Note that numerical results are rounded, so the values shown are not exact. Unnecessary precision is pointless, because everything can change quite significantly in a few seconds with real grid-connected mains power. For example, if you calculate the exact power dissipated in the load, it's a tiny bit higher than the simulator claimed because I rounded the numbers.

The capacitor is not switched into the circuit so is not part of the measured circuit at this time. It will be connected and the results analysed a little later. Here are the waveforms for the circuit shown in Figure 1. The voltage is 230V, 50Hz and the load current is 162mA - close enough. If we calculate the apparent power (more correctly known as Volt-Amps or just VA), we get ...
Apparent Power = V * I = 230V * 162mA = 37.25 VA
As seen in the graph, the actual average power is 26.25W - we are now able to perform the proper power factor formula, which applies in all cases - not just when we have nice convenient sinewave voltage and current waveforms. Accordingly, the cosΦ formula will not be used again - it is simply inappropriate and commonly gives totally wrong results with so many loads seen these days. A reactive load may be defined as any load where voltage and current have opposite polarities for part of a cycle. Look at the waveforms above and you'll see just that.
PF = Real Power (W) / Apparent Power (VA) = 26.25 / 37.25 = 0.705
In this case, the power factor works out the same (close enough) for both methods. This gives confidence that the processes and test circuits are correct. As noted, there are now two different ways to calculate power factor, but only the second version works with all supply and load voltage and current waveforms, and is therefore the only one that should be used. The old cosΦ formula is irrelevant and well past its use-by date, and should be dropped from all engineering curricula forthwith.
It's worth pointing out that contrary to what you will read from "power saver" websites, a power factor of 0.7 does not mean that your appliance is only operating at 70% efficiency. This is a common claim, and is complete nonsense. Power factor does not affect the efficiency of an appliance. Incandescent lamps have a unity power factor (i.e. perfect), yet are less than 5% efficient - the scammers won't tell you this of course.
With many electrical products, the poor power factor is well known and a capacitor is installed as part of the equipment itself. This is not common for household appliances because their overall contribution to the grid's power factor is small and there is (in general) no legislation that requires power factor correction (PFC) for domestic customers. The cap is shown in Figure 1, and when switched into the circuit it will draw about 108mA from the mains supply. This current has a leading power factor, and almost completely negates the reactive current caused by the appliance's inductance. Total mains current draw is 115mA with the capacitor connected - a reduction of 48mA. Power remains unchanged, but the current reduction can be quite dramatic. Note that when the cap is connected, the current through the load is not changed (contrary to the very silly claims of "cooler running appliances").
There is now an inductive load drawing 162mA and a capacitive load drawing 108mA, yet the total is 115mA. This is because the inductive reactive current and capacitive reactive cancel, and 115mA is drawn from the mains. The load itself continues to draw 162mA and dissipate 26.25W as before. This is seriously confusing to anyone who has not worked extensively with electrical installations, and is how the scammers have been able to convince so many people that their fraudulent devices do something that looks like magic. It is, however, completely real. You don't need to understand it, but you do have to know it happens in real circuits. Apparent power (VA) and power factor can be calculated ...
VA = V * I = 230 * 0.115 = 26.45 VA
PF = Real Power (W) / Apparent Power (VA) = 26.25 / 26.45 = 0.992
This is where the sellers of "power savers" either confuse themselves, or they use this information to confuse you, the purchaser. They only look at the current, and see that when a capacitor is connected, the current falls. Since most people know little or nothing about electricity and even less about power factor, it's easy to see how people can be convinced that these gadgets work. Since the current is lower, then my electricity bill must be smaller too, right?
WRONG! As domestic consumers, we are almost always charged only for the real part of the power we use. Worldwide, there may be some exceptions, but I have not seen definitive evidence that anyone, anywhere, is charged for apparent power (VA). Certainly, penalties apply for industrial and commercial users who fail to correct their power factor, but in many countries it would require an act of parliament to make such a far-reaching change to the way householders are billed for their power usage.
The humble (and very well known) capacitor is the basis of nearly all "power saver" claims, because mysteriously, the mains current falls when the capacitor is switched into the circuit. It is assumed (or claimed) that this drop in current represents a saving on your power bill. In reality, all that's been done is to improve the power factor by cancelling the reactive current. In almost all cases, your meter spins just as fast as it did before. There is (potentially) a small benefit to the power company, but only if the power factor correction is switched in and out as needed. If it's there all the time it does more harm than good!
While inductive loads are common, a far more common load in modern households is non-linear. Light dimmers are a good example, but many other products use switchmode power supplies (SMPS). PCs, microwave ovens, inverter air conditioners, small appliance chargers, compact fluorescent lamps, LED lamps are just a few examples. While some of these SMPS use power factor correction, most don't at this stage. You will notice that without fail, every single demonstration of a "power saver" shows it reducing the current drawn by an ordinary motor or perhaps a fluorescent lamp.
What you won't see is a demonstration of the unit "saving" power drawn by a computer or a dimmed incandescent lamp. There is a very good reason that they stay well away from these, because their device has zero effect, although in some instances it may make things worse. There are huge numbers of non-linear loads in most households these days, and in some cases you may not even see a traditional electric motor. Air conditioners and some washing machines commonly use electronic speed control for the motors, so they are no longer directly connected to the mains. Between the meter box and the motor is a whole box full of electronics.
For low power devices, these will have no power factor correction, because it adds to the cost. Larger units use a system called active power factor correction (PFC) - elaborate circuitry that ensures that the mains current is largely sinusoidal and in phase with the voltage. These circuits are complex, and have only recently become economically feasible due to the development of highly specialised integrated circuits that control high voltage circuitry with astonishing precision.
Since any home device that uses active PFC doesn't need a capacitor, the fraudulent "power saver" can do nothing. As noted above though, all other non-linear loads are avoided too, because a capacitor cannot correct the power factor of any non-linear load. Figure 4 shows a simplified representation of a non-linear load. It's not meant to represent anything in particular, but the power current and waveforms could be very similar to a notebook PC power supply for example.

After the AC is rectified by the four diodes, it is smoothed by the 18uF capacitor, and the only work (energy) that is expended is via the resistance. Although it is very common to represent the real part of the load with a resistance, it could be anything from an actual power resistor (used for heating) through to rotary movement twirling fan blades or lifting an elevator full of people (although for the latter case we can safely assume the circuit will draw somewhat more than 54W
).
A resistor is shown to indicate that work is performed. Perfect (or ideal) capacitors and inductors perform no work at all - they are energy storage devices that allow energy to be added or removed without losses. Real capacitors and inductors have losses, although they can be quite small with well engineered devices.

There is no easy way to calculate the waveforms, power factor or actual power, and it is far easier to measure it. I used a simulator, but a good power meter and oscilloscope will give the same result with a real electronic load that matches the above.
Actual power is 54W, but the VA rating (Volts * Amps drawn from the mains) is 92 VA. Power factor is therefore ...
PF = Real Power (W) / Apparent Power (VA) = 54 / 92 = 0.59
If we add a capacitor in parallel with the mains this time, the current does not fall, it rises. Power is unaffected. From the perspective of the "power saver" vendor, loads like this must be avoided, and you will never see a demonstration of their magic box reducing the current, because it cannot do so.
One thing that is critically important to understand is that the non-linear load causes power factor to be affected, even though the voltage and current are nominally in phase. This is something that even many electrical engineers seem to have problems with, and many forum arguments have raged over this very topic. The simple fact is that anyone who claims that non-linear loads do not adversely affect power factor is wrong, and I don't care how many university degrees they have - they are still wrong.
![]() | While it is claimed by "experts" from one end of the Net to the other, a diode bridge and capacitor filter as shown in Figure 3 is not a capacitive load, and does not cause a leading power factor. Look at the current waveform (green) - it's not a sinewave, and does not resemble a sinewave in any respect whatsoever. Nor is it leading the voltage waveform - peak current occurs before peak voltage, but that is irrelevant because it's not a sinewave! Only when both voltage and current waveforms are sinewaves of reasonable purity (harmonic distortion of no more than perhaps 10%) can the power factor can be leading or lagging. When one of the waveforms (typically current) is nothing like a sinewave, then phase angle is totally irrelevant to real power. There is no imaginary part because there is no reactive element, and no current is returned to the grid ... there can be no return (reactive) power because it's blocked by the diodes, so there is no leading power factor. Voltage and current are always the same polarity, so the load is not reactive. Period. This is a fact - anything else that you may see or hear is wrong. |
You will also see claims where the vendor fraudster talks about "excess power" coming into your home, and other unmitigated drivel. I have seen claims that this "excess power" causes appliance failure, and one of the lunatics selling this nonsensical junk claims that a single (36W) fluorescent lamp draws 300W without their magic box. What utter rubbish! Oh yes, it also has a "protruding wave device" (sic), whatever on earth that might be. Perhaps he forgot to zip his fly. It supposedly "protects your appliance from producing excess power and/or power surges". I call this word salad.
Almost all of the latest generation "power savers" are connected directly to the home switchboard, and their capacitance is across the AC line continuously. There are several things wrong with this, the first being that the "power saver" has absolutely no idea of how many inductive loads are connected, and indeed there may be none at all.
The capacitance remains across the mains at all times, and continues to draw mains current with a 90° leading power factor. If there is no reactive (inductive) load in use, the power company will experience a leading power factor that is as bad or worse than the normal lagging power factor they expect. If enough of these silly devices were used, the power company might possibly find itself with an uncorrectable leading power factor at some times during the day - this is actually worse than they expect because existing equipment can't correct for a leading power factor.
The purveyors of these magic boxes will never show the full mains current drawn when the motor or other load they use is disconnected. Why? Because it would show a continuous current from the mains even when nothing was turned on. They know that they can't have it both ways ... the box can't reduce your bill when stuff is connected, but have no effect when it just draws current by itself. No-one would fall for that, so the current drawn by the capacitors in the box is never mentioned.
Something else they don't tell anyone is just how much capacitance the box really has. If it's too much, their demonstrations will fail because the measured current will go up instead of down, so you can be fairly sure that the capacitance is selected to match the equipment actually used for the demonstrations. Even assuming that you have an inductive (phase shift) power factor problem, what are the chances that the magic box will be exactly right to bring the power factor back to unity?
How does the box even know that your load is connected so it can do its work? The answers are predictable - there is only a small chance that the box will provide the exact correction needed to obtain unity power factor, and it is simply connected to the line permanently whether it's needed or not.
One twit did (perhaps accidentally) disclose that his unit has a 6.8uF capacitor - roughly correct for a twin 36W fluorescent lamp fitting. It was also disclosed that the only other things in the box were a simple 5.1V DC power supply and a pair of LEDs. Strangely, there was no mention of any "protruding wave device" (sic) - (which would presumably be nothing more than a metal oxide varistor spike suppressor). How impressive.
There remains a serious problem. Exactly how much capacitance do you need to get a power factor of unity? This depends entirely on how much reactive current is drawn by your appliances at any given time. A fixed capacitance (as used in most "power savers") will only work for a constant reactive load of around the same reactance as the "demonstration" load. If the load is turned off, then the correct amount of capacitance needed falls to zero - the cap must be switched out of circuit, otherwise it is creating a poor leading power factor ... probably all the time.
If we use the example shown in Figure 1, we know that a capacitance of 1.5uF is correct. A 6.8uF cap (for example) would increase the total mains current to 393mA - more than double the current drawn by the load with no capacitor at all! This current has a leading power factor, and cannot be corrected by the power companies. If you paid for VA instead of Watts (as the scammers imply), adding the "power saver" would more than double the cost of operating this appliance. When the appliance was turned off, with 230V 50Hz mains the "power saver" would still be passing 490mA of reactive current (112.7VA) for no reason whatsoever.
Obviously, if the "power saver" has more capacitance, it will draw even more reactive current. Around 50uF of capacitance would be my expectation for a so-called "high power" unit for 230V, and perhaps 150uF for 60Hz/120V. Those will draw a current of 3.61A (830VA) at 230V/50Hz or 6.8A (816VA) at 120V/60Hz. The cap has to be bigger for 120V/60Hz operation, but the reactive losses will be similar.
Is this still looking like a good idea?
One very common claim is that much of the current drawn by a reactive appliance is "wasted". This is not the case at all - it is actually used by the real (resistive or in-phase) part of your machine to produce work ... actual power. If the current through the machine is reduced, so too is the available power. This is where the whole argument about motors "running cooler" falls apart at the seams.
Look again at Figure 1. The current through the load is 162mA, and the real and imaginary (reactive) parts are in series. It doesn't matter if the PFC cap is connected or not - the machine draws 162mA regardless. This means that the current through the resistive and reactive parts of the circuit is the same, as this is the only possible current path for a series connection. It's easy to calculate the power dissipated in the 1,000Ω (1k) resistor ...
P = I² * R = 0.162² * 1,000 = 26.25W (close enough)
If the PFC cap "made the machine run cooler" it would have to reduce the current through the machine, and this would reduce the real power. A clearly silly premise that does not happen. The full current drawn (162mA) is required and used by the load - none of it is "wasted".
When a capacitor of the correct value is connected directly across the motor, the overall mains current is reduced as we saw above, and the extra current needed by the inductive part of the load is provided by the capacitor instead of the mains wiring. The current demand of the machine itself is unchanged, but we've tricked the circuit by adding the cap so that the reactive currents (inductive and capacitive) cancel.
We know that the laws of conservation of energy are intact, because the power drawn from the mains now simply equals the product of volts * amps (VA). The machine is no more efficient, runs no cooler, provides no more power and does not rely on "free energy". We have simply used science to make the overall system more power-grid-friendly.
Even though we have done the power company a real service, there is no reward for residential and most small business customers. We are charged for the power used (kWh), not the reactive component (kVAr). However, there are exceptions! Consider the following ...
If you have your own solar or wind system with battery storage and an inverter, you become the "grid" and it is important that you maximise the power factor of all inductive loads. This is done at each machine and after its power switch (manual or automatic). It cannot be done on a "whole house" basis unless you have a sophisticated PFC cabinet that includes microprocessor monitoring and control. Silly boxes sold over the Net need not apply.
Power factor now becomes important because your inverter has to provide the full output in VA (proper inverters and alternators are rated in VA, not Watts). If your appliances have a poor power factor, the inverter still has to provide the total load (volts times amps), and its efficiency is reduced. This is why power companies have PFC at sub-stations and why they penalise industrial/commercial users for poor power factor. Householders (for the time being) get a free run.
All lighting should be low voltage DC - remember that it is extremely difficult to correct non-linear loads such as mains (AC) powered CFLs, but LEDs with DC is easy and power factor does not apply to DC power systems.
One of the hot topics at the moment seems to be "dirty electricity". Compact fluorescent lamps seem to be singled out as a major generator of dirty electricity according to some websites, but according to other believers it can come from anywhere. The claimed effects are astonishing, and range from "general malaise" right through to cancer. There are even meters that purport to show just how "dirty" one's electricity is supposed to be, and any number of people will give you all manner of "advice" as to what should be done.
It goes without saying that there is absolutely no proof one way or another, and there are no official measurements, standards or limits - any noise on the mains can be deemed "dirty", depending entirely on who is telling the story.
At least one "power saver" claims that it will eliminate "dirty electricity", and shows a wholly unconvincing before and after graph that allegedly demonstrates what the unit does. The "graph" is almost certainly hand-drawn, and shows nothing that makes the slightest bit of sense. This doesn't stop the lunatics selling the unit from proclaiming the benefit though. This particular unit's website even has an explanation for power factor that is wrong in almost all respects ("good" amperes and "bad" amperes - good grief!).
According to the 100% non-scientific drivel seen on websites, a "bad" amp is the reactive component that performs no useful work. Those who sell these fraudulent products completely ignore the fact that the "bad" current is simply a fact of life in the way the machines work. It is cured (by real engineers) by adding capacitance directly in parallel with the machine itself - after the power switch! Installing an overpriced box at the switchboard achieves nothing useful for the vast majority of the time, and will not save you a cent.
Claims for "cleaning" the incoming mains are specious - yes, a capacitor and optional surge suppressor devices (called Metal Oxide Varistors (MOVs)) will remove some high frequency noise from the mains, but the "cleaning" effect will be rather small in almost all cases. To be able to "clean" the mains effectively means that the device in parallel with the incoming mains should have an impedance that's no more than the line impedance for noise - preferably much less. The problem is that no-one knows the impedance of the mains for noise signals, because it will be different for virtually every installation.
Many electricity suppliers use something called "ripple control" which is used to control the load at the customer premises. Ripple control is still used extensively in Australia to control off-peak hot water systems and under-floor heating (for example). If the "power saver" works too well, it might conceivably render the ripple control systems ineffective - that would be an unexpected consequence that most users would consider unacceptable. Presumably, none of the "power savers" cleans the mains well enough to remove the ripple control frequencies, and I would fully expect that they would be just as (in)effective removing other noise as well.
This was just too priceless, and I had to include it in full ... "There are a few Power Saver models on the market but they all work along the same principle. They store the electricity inside of it using a system of capacitors and they release it in a smoother way to normal without the spikes. The systems also automatically remove carbon from the circuit which also encourages a smoother electrical flow. This means that you will have less power spikes. More of the electricity flowing around your circuit can be used to power your appliances than before."
Removes carbon ??? What utter nonsense is this? I have never read such drivel in all my life, and this is meant to be taken seriously.
A favourite claim is that by using the "power saver", your appliances will run cooler and last longer. As noted above (see "Wasted Current"), this is unmitigated horse feathers - no form of reactive power factor correction changes what happens inside the machine. Not one iota! All that is changed is the current drawn from the mains, the machine changes the power factor as a result of having a reactive element - an external capacitor does not and can not change the relationship between voltage and current inside the machine itself. If this happened, it would be quite absurd - adding a capacitor in parallel with a device would completely change the way the machine actually works - a ludicrous proposition at best considering that the AC mains are an extremely low impedance voltage source.
![]() | However ... in some cases there might be a very small improvement, but generally very limited in any residential/small business environment. If the mains is especially noisy and contains significant harmonic currents, a small number of motors might run warmer than expected. This is uncommon, and it is generally unlikely that you would ever notice. Needless to say, large industrial/commercial systems may be different, but they require a proper engineered solution, not a pissant little box bought from an internet seller. |
All sellers of these fraudulent devices are either clueless believers or calculating thieves. There is no middle ground here, none of the devices work at all for 99.99% of residential customers, and industrial or commercial users would be penalised for creating a leading power factor whenever the motors or uncorrected fluorescent lamps fittings are not in operation (these are two of the main causes of poor power factor). However, most fluorescent "troffers" (as they are known in the industry) used in commercial or industrial installations already have PFC capacitors installed!
Not long after this article was published, I was contacted by a chap who works with real industrial power factor correction systems [5]. These are not silly toys, but serious cabinets intended to correct the power factor to prevent (or at least mitigate) power company penalties for unacceptable phase angles on the grid. One of the things that is a real concern is harmonic current, caused by non-linear loads.
If this current is high enough, it will exceed the PFC capacitor ratings and cause failure. This can (and sometimes does) result in a fire in the PFC cabinet, despite measures taken to limit the high frequency current to safe limits. Typically, an inductor is used in series with the capacitor, so the total impedance rises for high frequency harmonics on the power line. Typical sources of these high frequency harmonic currents are variable frequency drives, large (and older style) switchmode power supplies, uninterruptible power supplies and many other electronic loads.
The reactance of a capacitor falls with increasing frequency, so while a 20uF capacitor has a reactance of 159 ohms at 50Hz, this falls to 53 ohms at the third harmonic (150Hz), and only 32 ohms at the fifth harmonic (250Hz). Larger capacitors have lower impedances. Adding a small inductor prevents the impedance falling so far that dangerous harmonic currents can be created at higher frequencies.
When you look at the current waveform of the simple electronic load in Figure 3 (the green trace in Figure 4), that waveform is rich in harmonics. There are specific conditions that can arise with any electrical installation where the results are best described as unexpected - very strange things happen that may not have been predicted. Problems with harmonic current is one such anomaly, and you can be fairly certain that the vast majority of "power savers" do not consider any of the things that can go wrong. The likelihood of any of them including a harmonic current limiting inductor is exceptionally small, and the only thing that prevents excessive current is the rather modest capacitance that you can expect to find inside.
If a "power saver" with no protective circuitry were to catch on fire and burn down your house, do you think your insurance company would just cheerfully pay up?
A second issue is possibly lethal. All "power saver" claims include the assertion that the units draw no power themselves. This means that an essential component must be omitted - a bleeder resistor. This is connected in parallel with the capacitor and ensures that any stored voltage will be discharged quickly enough to prevent possible injury or death to anyone working on the electrical installation. It is probable that the vast majority of these units have no safety provisions at all.
If this essential safety resistor is fitted, the "power saver" will actually consume a small power (perhaps 2-5W), 24 hours a day, seven days a week, even if everything inside the house is switched off. As a result, it will cost you money to have it connected, but will still not save a cent.
All of these risks need to be assessed, but in the end, you don't need to bother. The units don't work and will not reduce your power bill, they are comparatively expensive, so why would you ever install one?
It is important to understand that this "power saver" technology is not new, and is done - properly - by many professional engineering companies all over the world. A photo of a professional unit is shown below, and this contains all the things that are actually needed. None of the required items are included in the toys sold by scammers.

The harmonic current limiting inductor is clearly visible - see how small and cheap that would be? No, this is a serious piece of steel and copper, and is a heavy and expensive part. You will not find this inside any of the "power savers" though, because it would cost too much. Likewise, you won't find any sophisticated computer-based controller that switches units such as that pictured in and out of circuit as required to maintain the best possible power factor. The unit pictured uses contactors (very big relays) to switch the caps in and out as needed, but some other systems use solid-state switching. The point here is that the capacitance is adjusted as needed to optimise the power factor. It's not just a shiny box that connects directly across the mains and is left there permanently.
Power factor correction is real technology that's simply been hijacked, used in a manner for which it was never intended, cut down, cheapened and lied about. It's probably a fairly easy sell too, because very few people know enough about electricity and distribution systems. This makes them easy prey, because demonstrations will appear to be real. Certainly looking real enough to fool Australian TV stations who aired shameless Public Relations company footage showing how these frauds will "save you money".
The unit shown in the photo above is made by Alstom, and is sold in Australia by IDP Industrial Products. This has nothing in common with the "power savers" you see offered, this is part of a real industrial solution, and is engineered to perform its task.
The backlash against the TV stations has been excellent, with many people complaining bitterly about their promotion of fraudulent products.
First and foremost, I can prove and demonstrate every single claim I have made, with reasonably high precision instruments, a simulator, and other sophisticated test equipment. I have described each simulated test with more than sufficient information for anyone to duplicate what I've done, and I have made no general assumptions. This is all actual and demonstrable science, and does not rely on hyperbole, lies or twisted logic. Capacitors connected across the mains do not "store energy for later use" any more than they can provide free energy.
It's actually hard to know for certain if those selling these devices actually believe that they work (plausible but unlikely) or they know full well that they don't and are simple charlatans who want only to separate you from your money. Either way, the devices don't work and won't save you money. They will cost you money though, for purchase and installation, and for decommissioning prior to you obtaining the promised refund (hopefully, but don't hold your breath). Electrical safety concerns should be enough to ensure that no-one ever installs one of these pointless boxes.
If the premise that you pay for reactive current were true, then installing one of these devices would cost you far more to run (continuously) that you would pay without it. The reason is simple. You may have a couple of motor loads that run for a few hours each day, and the "power saver" might (might) reduce the current drawn by a small amount.
The rest of the time, the "power saver" is still connected, and is drawing its own reactive current ("bad" amps according to one supplier) continuously. If the device uses a 20uF capacitor for example (50Hz 230V mains), it will draw 1.44A ("bad" amps) continuously, 24 hours a day, 7 days a week with what's known as a leading power factor.
For 60Hz 120V mains, the cap might be 40uF (yes, I'm guessing, but my silly guesses are just as good as their silly guesses). This will draw 1.8A (also "bad" amps of course) 24/7.
The constant leading power factor may even annoy the supply authorities to the extent that they could demand that it be removed forthwith or they will disconnect you from the grid. This is especially true if it interferes in any way with ripple control apparatus that may be installed in your meter box (this may also include so-called "smart meters").
The charlatans claim that we pay for the "bad" amps drawn by our appliances, but strangely we don't pay for the "bad" amps the "power saver" box creates. This conundrum is easily avoided by never disclosing that the device draws any current - all demonstrations are carefully conducted to ensure that we never see the "bad" current drawn by the PFC capacitor. Expect to be told that this is "German Engineering" or is from some other advanced country (the US is also a favourite for those outside the US). The implication is that it must somehow be "good" if engineered in (insert impressive sounding country) - presumably as opposed to Outer Mongolia for example. You will find these cons on websites all over the world, and eBay is riddled with them (but will take no action it seems, even though this is a well known fraud).
You have every right to be highly suspicious - these devices do not work, and claims that industry has been using them for years is simply false. Industry is expected to install complex and expensive equipment that provides full monitoring and adjusts itself to provide an acceptable power factor back to the grid - it's a lot more sophisticated than a box with a light emitting diode and a couple of capacitors!
In short, if the device simply plugs into a power outlet, or is wired into your switchboard without input and output connections, it cannot possibly work as claimed. Some devices are wired in series with the equipment being controlled, and some of these might have some validity under certain limited circumstances. There is a class of device that supposedly monitors the power and adjusts the voltage so that the motor (and these systems only work with motors) gets the power it needs and no more. Personally, I'd be very wary indeed - the available information is sketchy, and I'd be very concerned for the health of my motor(s) if they are forced to run on a reduced voltage. Most appliance makers have been building their equipment for a long time, and I'd trust their engineers over an unknown website owner and/or backyard "inventor" every time.
As a final comment, consider that if these devices actually saved power, then major electrical goods outlets, electrical wholesalers and big department stores would be selling them. The big electrical goods suppliers would never let an opportunity like this pass - they would be crazy to let such a product be sold through shonky websites and eBay and not cash in themselves if there was any chance that they worked. However, you can't buy one from any of the major retailers - anywhere. Nor are power companies giving them away as they did with compact fluorescent lamps ... There must be a reason.
That reason is simple - they all know that the products are a con, and they don't save anyone (including the power company) a cent. If they were to sell this rubbish, they would be prosecuted by the consumer protection bureau of every major country where they were sold (there has been one known exception to this, where a "power saver" unit was sold but quickly withdrawn by a major retailer). The shonky website operators and eBay sellers can simply vanish or declare their company bankrupt when ordered to repay the people who have been sucked in by the false promises.
If you still think they work, I have this really great bridge for sale ...
Links marked with an asterisk (*) are Australian Competition & Consumer Commission (Australian Government) web pages.
The list of scammers is obviously severely cut down and is intended as an example. There are thousands of sites on the Net, all making similar pointless and false claims.
It seems that there may be a bit of a stoush between the first two scammers (8 and 9) listed above. Various forum sites and newsgroups have references to differences of opinion, right up to breach of confidentiality. What can possibly be confidential? The scam is well known, the use of capacitors is well known and that fact that they don't work is well known. Personally, I think it's pretty funny that scammers are fighting with each other over their scam.